About Us
Monosplit air conditioning installation kit
2 m of 1/4" pre-insulated copper pipe
2 x 1/4" self-flaring fittings
2 m of 1/2" pre-insulated copper pipe
2 x 1/2" self-flaring fittings
2 m of condensate pipe
2 m of 4x1.5 four-pole cable
1 support per 105 kg mono external unit
Copper tube characteristics:
Annealed ACR (R220), mechanical characteristics, dimensions, tolerances and eccentricity compliant with UNI EN 12735-1.
Can be used with R407C and R410A refrigerants, internal cleaning and dehumidification under inert gas with a maximum total residue of 0.034 g/m² and sealed ends in accordance with ASTM B280.
Coating
Insulating sheath made of physically cross-linked closed-cell expanded polyethylene with the following technical values:
- thermal conductivity at 40 °C λ ≤ 0.040 W/m*K
- Water vapour diffusion resistance factor (anti-condensation) μ ≥ 10000
- Fire reaction: class 1
- Operating temperature -80 °C / +120 °C
- does not contain CFCs
White extruded polyethylene (LDPE) outer film, with flame retardant additive, adhering to the foam to ensure a high level of anti-condensation, excellent abrasion and tear resistance.
Load capacity: 105 kg
2 anti-release safety stops
Spirit level included
2 anti-vibration supports to be placed between the supports and the wall
3 dowels with screws and washers
4 anti-vibration feet to be placed between the air conditioner and the supports for optimal sound insulation
Self-flaring fitting characteristics:
The metallic seal and the operating pressure of up to 140 bar make this product particularly suitable for refrigeration and air conditioning systems operating with new refrigerants with low environmental impact for connecting pipes, valves, tanks and general piping components.
The clamping ring acts like a vice on the external surface of the pipe to withstand pressure and create an effective seal.
Characteristics:
- Fluid temperature: from -40 °C to +150 °C
- Maximum operating pressure: 140 bar
- Compatible with traditional 45° flared fittings
- It is not necessary to calibrate or flare the pipe end, nor to tighten it with a torque wrench. Approvals:
- CE (PED, RoHS, REACH), EAC
- Performance superior to the requirements of DIN 8912 and SAE J513 standards for traditional 45° flared fittings Patented system style="font-size:16px;">ELECTRICAL CABLE CHARACTERISTICS
Four-pole cable for 220 V single-phase power supply to air conditioners
Product code: KI.2.1/4-1/2
Monosplit air conditioning installation kit
2 m of 1/4" pre-insulated copper pipe
2 x 1/4" self-flaring fittings
2 m of 1/2" pre-insulated copper pipe
2 x 1/2" self-flaring fittings
2 m of condensate pipe
2 m of 4x1.5 four-pole cable
1 support per 105 kg mono external unit
Copper tube characteristics:
Annealed ACR (R220), mechanical characteristics, dimensions, tolerances and eccentricity compliant with UNI EN 12735-1.
Can be used with R407C and R410A refrigerants, internal cleaning and dehumidification under inert gas with a maximum total residue of 0.034 g/m² and sealed ends in accordance with ASTM B280.
Coating
Insulating sheath made of physically cross-linked closed-cell expanded polyethylene with the following technical values:
- thermal conductivity at 40 °C λ ≤ 0.040 W/m*K
- Water vapour diffusion resistance factor (anti-condensation) μ ≥ 10000
- Fire reaction: class 1
- Operating temperature -80 °C / +120 °C
- does not contain CFCs
White extruded polyethylene (LDPE) outer film, with flame retardant additive, adhering to the foam to ensure a high level of anti-condensation, excellent abrasion and tear resistance.
Load capacity: 105 kg
2 anti-release safety stops
Spirit level included
2 anti-vibration supports to be placed between the supports and the wall
3 dowels with screws and washers
4 anti-vibration feet to be placed between the air conditioner and the supports for optimal sound insulation
Self-flaring fitting characteristics:
The metallic seal and the operating pressure of up to 140 bar make this product particularly suitable for refrigeration and air conditioning systems operating with new refrigerants with low environmental impact for connecting pipes, valves, tanks and general piping components.
The clamping ring acts like a vice on the external surface of the pipe to withstand pressure and create an effective seal.
Characteristics:
- Fluid temperature: from -40 °C to +150 °C
- Maximum operating pressure: 140 bar
- Compatible with traditional 45° flared fittings
- It is not necessary to calibrate or flare the pipe end, nor to tighten it with a torque wrench. Approvals:
- CE (PED, RoHS, REACH), EAC
- Performance superior to the requirements of DIN 8912 and SAE J513 standards for traditional 45° flared fittings Patented system style="font-size:16px;">ELECTRICAL CABLE CHARACTERISTICS
Four-pole cable for 220 V single-phase power supply to air conditioners
Product code: KI.2.1/4-1/2
Installation kit for monoblock air conditioner - 2m 1/4'' + 1/2'' copper pipe with wall mount
SKU:KI.2.1/4-1/2
- Regular price
- 64,77 €
- Sale price
- 64,77 €
- Regular price
-