{"product_id":"activateur-gsm-pour-les-utilisateurs-delectricite-via-sms-ou-application","title":"GSM Activator for Electricity Users via SMS or App","description":"\u003cdiv class=\"ProductDescription\"\u003e\n\n\u003cdiv class=\"content\" itemprop=\"description\"\u003e\n\u003cp align=\"center\"\u003e\u003cspan style=\"font-size: 18pt; color: #ff0000;\"\u003e\u003cspan style=\"color: #f30094;\"\u003e\u003c\/span\u003eGeca GSM ACTIVATOR\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003cspan style=\"font-size : 14pts; color: #0000ff;\"\u003eremote control of electrical devices\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003cspan style=\"font-size: 14pt; couleur : #0000ff;\"\u003evia SMS or app from SMARTPHONE or TABLET\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003cimg alt=\"GSM Activator for users of\" application=\"\" geca gsm03=\"\" height=\"625\" or=\"\" sms=\"\" src=\"vertumart\/product\/GSM03_W.jpg\" via=\"\" width=\"625\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\u0026lt; p \u0026gt;\u003cspan style=\"color: #ff0000; font-size: medium;\"\u003eGSM ACTIVATEUR 03 Geca\u003c\/span\u003e\u003cp style=\"margin-bottom: 0cm; line-height: 150%; text-align: left;\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003cspan style=\"color: #000000;\"\u003eGSM controller that allows you to remotely activate or deactivate devices such as boilers, chronothermostats, fan coils, air conditioners, alarm systems, gates, etc. via a simple SMS or a free phone call. The GSM 03 activator is equipped with 2 relay outputs and 3 dry contact alarm inputs, thanks to which it is possible to immediately notify the user of a possible boiler blockage, power failure or restoration, alarm system intervention (theft, gas, fire), etc.\u003c\/span\u003e\u003cbr\u003e \u0026lt; span style ='color: #000000;'\u0026gt;Thanks to the GSM03 buffer battery, it is able to signal the power failure and restoration.\u003c\/span\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0cm; line-height: 150%; text-align: left;\"\u003e\u003cspan style=\"font-size: 12pt; color: #000000;\"\u003eTECHNICAL DATA\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0cm; line-height: 150%; text-align: left;\"\u003e\u003cspan style=\"font-size: 12pt; color: #000000;\"\u003ePower supply 12 Vac\/dc - I max 500 mA (transformer not included in the package)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0cm; line-height: 150%; text-align: left;\"\u003e\u003cspan style=\"font-size: 12pt; color: #000000;\"\u003e2 relay outputs\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0cm; line-height: 150%; text-align: left;\"\u003e\u003cspan style=\"font-size: 12pt; color: #000000;\"\u003eOutput power Class 4 (2 w at 850\/900 MHz) Class 1 (1 w at 1800\/1900 MHz)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0cm; line-height: 150%; text-align: left;\"\u003e\u003cspan style=\"font-size: 12pt; color: #000000;\"\u003eSensitivity 107 dBm at 850\/900\/1800\/1900 MHz\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0cm; line-height: 150%; text-align: left;\"\u003e\u003cspan style=\"font-size: 12pt; color: #000000;\"\u003eRechargeable Li-Ion POLY 3.7V-500 mA battery\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0cm; line-height: 150%; text-align: left;\"\u003e\u003cspan style=\"font-size: 12pt; color: #000000;\"\u003eUser management Yes (with optional password)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0cm; line-height: 150%; text-align: left;\"\u003e\u003cspan style=\"font-size: 12pt; color: #000000;\"\u003eExternal antenna yes \u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0cm; line-height: 150%; text-align: left;\"\u003e\u003cspan style=\"font-size: 12pt; color: #000000;\"\u003eMonostable relay 8 A - 250 Vca\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0cm; line-height: 150%; text-align: left;\"\u003e\u003cspan style=\"font-size: 12pt; color: #000000;\"\u003eControl type APP, SMS, ringtone or manual\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0cm; line-height: 150%; text-align: left;\"\u003e\u003cspan style=\"font-size: 12pt; color: #000000;\"\u003e3 dry contact inputs\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0cm; line-height: 150%; text-align: left;\"\u003e\u003cspan style=\"font-size: 12pt; color: #000000;\"\u003eTemperature control Yes\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0cm; line-height: 150%; text-align: left;\"\u003e\u003cspan style=\"font-size: 12pt; color: #000000;\"\u003e(internal or external probe)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0cm; line-height: 150%; text-align: left;\"\u003e\u003cspan style=\"font-size: 12pt; color: #000000;\"\u003eProgramming via APP\/SMS\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0cm; line-height: 150%; text-align: left;\"\u003e\u003cspan style=\"font-size: 12pt; color: #000000;\"\u003eDimensions 140x85x44 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0cm; line-height: 150%; text-align: left;\"\u003e\u003cspan style=\"font-size: 12pt; color: #000000;\"\u003eReference standards EN 301489-7 \/ EN 301511 \/ EN 60950\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0cm; line-height: 100%; text-align: left;\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e \u003c\/p\u003e\n\u003cp align=\"LEFT\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct code: GSM03\u003c\/span\u003e\u003c!-- strong--\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"LEFT\"\u003e \u003c\/p\u003e\n\u003cp align=\"LEFT\"\u003e\u003ca href=\"\/en\/virtuemart\/product\/Manuale_GSM03.pdf\" target=\"_blank\" title=\"Manuel d\" utilisation\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003cspan style=\"font-size: 10pt; \"\u003e\u003cimg alt=\"the manual\" src=\"t\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!-- strong--\u003e \u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cp align=\"LEFT\"\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"TECNOCONTROL","offers":[{"title":"Default Title","offer_id":61610231005514,"sku":"GSM03","price":139.97,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0998\/0857\/5818\/files\/8f8504ab2a013f01.jpg?v=1781201927","url":"https:\/\/supertechnostore.com\/en\/products\/activateur-gsm-pour-les-utilisateurs-delectricite-via-sms-ou-application","provider":"Supertechnostore","version":"1.0","type":"link"}